High Concentration Hydrogen Sulfide Sensor (H2S Sensor) - H2S-BE

? Range: 2,000 ppm H2S limit of performance warranty
? Sensitivity: nA/ppm in 200ppm H2S
? Response time t90: < 50? (s) from zero to 200ppm H2S
? Resolution: < 0.5 RMS noise (ppm equivalent)
? Temperature range : -30 to 50 ℃
? Pressure range : 80 to 120 kPa
? Humidity range : 15 to 90 % rh continuous
? Weight : < 13 g

  • Model Number: H2S-BE
  • Data Sheet: Date Sheet File
Quantity:
- +
  • High Concentration Hydrogen Sulfide Sensor (H2S Sensor)
  • High Concentration Hydrogen Sulfide Sensor (H2S Sensor)
Mouse over image to zoom
Share:

Product Specification

H2S-BE Hydrogen Sulfide Sensor (H2S Sensor) Description
Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.

H2S-BE Hydrogen Sulfide Sensor size:
32mm diameter package, the best choice for fixed site applications

With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.

H2S-BE Hydrogen Sulfide Sensor (H2S Sensor) PERFORMANCE
Sensitivity
nA/ppm in 200ppm H2S
80 to 115
Response time
t90 (s) from zero to 200ppm H2S
< 50
Zero current
ppm equivalent in zero air
< ± 3
Resolution
RMS noise (ppm equivalent)
< 0.5
Range
ppm H2S limit of performance warranty
2,000
Linearity
ppm error at 2000ppm, linear at zero and 400ppm H2S
< 30
Overgas limit
maximum ppm for stable response to gas pulse
10,000



H2S-BE Hydrogen Sulfide Sensor (H2S Sensor) LIFETIME
Zero drift
ppm equivalent change/year in lab air
< 0.25
Sensitivity drift
% change/year in lab air, monthly test
< 3
Operating life
months until 80% original signal  (24 month warranted)
> 24



H2S-BE Hydrogen Sulfide Sensor (H2S Sensor) ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 200ppm
83 to 92
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 200ppm
102 to 112
Zero @ -20°C
ppm equivalent change from 20°C
< ± 4
Zero @ 50°C
ppm equivalent change from 20°C
< ± 4



H2S-BE Hydrogen Sulfide Sensor (H2S Sensor) CROSS SENSITIVITY
NO2   sensitivity
% measured gas @ 10ppm NO2
< -25
Cl2     sensitivity
% measured gas @ 10ppm Cl2 
< -12
NO     sensitivity
% measured gas @ 50ppm NO
< 10
SO2   sensitivity
% measured gas @ 20ppm SO2
< 20
CO     sensitivity
% measured gas @ 400ppm CO
< 4
H2     sensitivity
% measured gas @ 400ppm H2
< 0.2
C2H4 sensitivity
% measured gas @ 400ppm C2H4
< 0.25
NH3   sensitivity
% measured gas @ 20ppm NH3
< 0.1



H2S-BE Hydrogen Sulfide Sensor (H2S Sensor) KEY SPECIFICATIONS
Temperature range
°C
-30 to 50
Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in sealed pot)
6
Load resistor
Ω (recommended)
10 to 47
Weight
g
< 13

Matched Transmitter board for H2S-BE H2S Sensor

4-20mA Analogue Transmitter Board
  ? Factory calibration, custom-set for immediate use
  ? Wide operating voltage range
  ? Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.


4-20mA Digital Transmitter Board
   ? Factory calibration, custom-set for immediate use
   ? Digital zero, sensitivity and temperature compensation
   ? Digital and 4-20mA output
   ? Biased or unbiased operation
   ? Calibration and range change

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
久久99精品国产| 日韩av无码国产精品| 亚欧无码精品无码有性视频| 亚洲精品福利视频| heyzo加勒比高清国产精品| 国产精品久久久久久福利69堂| 香蕉伊思人在线精品| 国产精品久久国产精麻豆99网站 | HEYZO无码综合国产精品| 精品少妇无码AV无码专区| 精品久久久久久久久久久久久久久| 国产精品三级视频| 精品一区二区在线观看| 任我爽精品视频在线播放| 国产手机精品一区二区| 99精品一区二区三区| 国产精品综合久成人| 日韩久久精品一区二区三区| 91久久精品视频| 亚洲国产精品无码久久久秋霞2 | 91精品在线播放| 国产精品亚洲精品爽爽| 国产精品高清视亚洲一区二区| 午夜不卡久久精品无码免费| 久久精品国产亚洲精品| 精品乱码一区内射人妻无码| 久久精品无码一区二区三区不卡| 91国内揄拍国内精品情侣对白 | 精品久久久久久中文字幕| 亚洲精品一级无码中文字幕| 蜜臀91精品国产高清在线观看| 国产精品蜜芽在线观看| 久久99精品久久只有精品| 久久99热精品这里久久精品| 亚洲精品乱码久久久久久| 国产精品美女久久久久av爽| 国产女精品视频在ktv| 热久久综合这里只有精品电影| 任我爽橹在线精品视频| 亚洲制服丝袜精品久久 | 亚洲AV无码成人精品区日韩 |