Oxygen Gas Sensor (O2 Sensor) - 4OXV CiTiceL

? Measurement Range: 1-25% vol. O2
? Output Signal: 0.10 ± 0.02 mA in Air
? Response Time (T90): <15 Seconds
? Operating Temperature Range: -20°C to +50°C
? False alarm immunity
? Enhanced response time in extreme applications
? Reliably meets stated life
? Superior environmental performance

  • Model Number: 4OXV CiTiceL
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Oxygen Gas Sensor (O2 Sensor)
  • Oxygen Gas Sensor (O2 Sensor)
  • Oxygen Gas Sensor (O2 Sensor)
Mouse over image to zoom
Share:

Product Specification

4OXV CiTiceL Oxygen Gas Sensor (O2 Sensor) Key Features and Benefits:
? False alarm immunity

? Enhanced response time in extreme applications
? Reliably meets stated life
? Superior environmental performance

4OXV CiTiceL Oxygen Gas Sensor (O2 Sensor) Technical Specifications

MEASUREMENT
Technology Electrochemical
Measurement Range 1-25% vol. O2
Maximum Overload 30% vol. O2
Output Signal 0.10 ± 0.02 mA in Air
Response Time (T90) <15 Seconds
Zero Current (Offset) <0.6% vol. O2
Linearity

Can be considered linear in many cases.
See Operating Principles (OP-02) for further details.



ELECTRICAL
Recommended Load Resistor 100 ?


MECHANICAL
Casing Material ABS
Weight <16 g
Orientation Sensitivity <0.2% vol. O2 equivalent


ENVIRONMENTAL
Operating Temperature Range

-20°C to +50°C (up to 3 months continuous across RH range)

Recommended Storage Temp  0°C to 20°C
Thermal Transient
(Temp. plunge +22°C to -20°C)
<23.5% vol. O2
Operating Pressure Range Atmospheric ± 20%
Pressure Coefficient <0.02% signal/mbar
Pressure Transient  
(60 cm H2O step change) 
<200% signal change
Relative Humidity Range (at 0°C to 20°C)
Continuous 5 to 95%RH non-condensing
Short Term 0 to 99%RH non-condensing


LIFETIME
Long Term Output Drift <2% signal/month
 Typically <5% over operating life
Expected Operating Life Minimum 24 months in air
Storage Life 6 months in original packaging
Warranty Period 24 months from date of despatch

4OXV CiTiceL Oxygen (O2) Gas Sensor IMPORTANT NOTES
Obstruction of the vent hole will compromise performance, and must be avoided. Do not remove label.

Adequate free volume should be provided below the sensor to ensure full performance.

All tolerances ±0.15 mm unless otherwise stated.DO NOT solder to pins.

All performance data is based on conditions at 20oC,50% RH and 1013 mbar

4OXV CiTiceL Oxygen Gas Sensor (O2 Sensor) Typical Applications
General purpose, portable or fixed life safety.

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
精品人妻少妇一区二区三区不卡 | 精品综合一区二区三区| 国产成人精品亚洲| 国产在线精品二区赵丽颖| 国产精品成人va在线播放| 精品国产一区二区三区久久影院| 国产精品久久久香蕉| 国产免费久久精品99re丫y| 99久久精品午夜一区二区| 精品久久久久久成人AV| 久久99热这里只频精品6| 亚洲精品人成网在线播放影院| 亚洲精品无码久久久久秋霞| 欧美精品久久久久a片一二三区| 国产成人精品三级在线| 国产成人精品123区免费视频| 亚洲精品专区在线观看| 人妻少妇无码精品视频区| 久久精品成人国产午夜| 久久免费观看国产99精品| 91精品国产乱码在线观看| 国产精品揄拍一区二区| 美女精品永久福利在线| jazzjazz国产精品一区二区| 91精品视频网站| 精品一久久香蕉国产二月| 精品少妇人妻AV无码专区不卡| 国内精品久久久久影院蜜芽| 人妻精品久久久久中文字幕| 国精品产露脸自拍| 久视频精品免费观看99| 亚洲首页国产精品丝袜| 狠狠入ady亚洲精品| 中文字幕精品无码一区二区 | selao久久国产精品| 91精品日韩人妻无码久久不卡| 久久精品黄AA片一区二区三区| 3atv国产精品视频| 亚洲精品专区在线观看| 日韩人妻无码精品久久免费一| 亚洲乱码一区二区三区国产精品|