Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode - H2S-A4

? Range: 50 ppm H2S limit of performance warranty
? Sensitivity: 1400 to 1850? nA/ppm at 2ppm H2S
? Response time t90: < 45s from zero to 2ppm H2S
? Temperature range: -30 to 50 ℃
? Pressure range: 80 to 120 kPa
? Humidity range: 15 to 90 % rh
? Weight: < 6? g

  • Model Number: H2S-A4
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode
  • Hydrogen Sulfide Sensor (H2S Sensor) 4-Electrode
Mouse over image to zoom
Share:

Product Specification

H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) Description
Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.

H2S-A4 Hydrogen Sulfide Sensor size:
20mm diameter, the industry standard size for portable gas detectors

With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.

H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) PERFORMANCE
Sensitivity
nA/ppm at 2ppm H2S
1400 to 1850
Response time
t90 (s) from zero to 2ppm H2S
< 45
Zero current
nA in zero air at 20°C
-250 to 100
Noise*
±2 standard deviations (ppb equivalent)
5
Range
ppm H2S limit of performance warranty
50
Linearity
ppb error at full scale, linear at zero and 10ppm H2S
< ± 0.5
Overgas limit
maximum ppm for stable response to gas pulse
100
* Tested with Alphasense AFE low noise circuit



H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) LIFETIME
Zero drift
ppb equivalent change/year in lab air
< ±100
Sensitivity drift
% change/year in lab air, monthly test
< 20
Operating life
months until 50% original signal (24 month warranted)
24



H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) ENVIRONMENTAL
Sensitivity @ -20°C
(% output @ -20°C/output @ 20°C) @ 2ppm H2S 
80 to 92
Sensitivity @ 50°C
(% output @ 50°C/output @ 20°C) @ 2ppm H2S
100 to 110
Zero @ -20°C
nA change from 20°C
30 to 50
Zero @ 50°C
nA change from 20°C
90 to 110



H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) CROSS SENSITIVITY 
NO2  sensitivity
% measured gas @ 5ppm NO2
< -20
Cl2    sensitivity
% measured gas @ 5ppm Cl2
< -8
NO    sensitivity
% measured gas @ 5ppm NO
< 3
SO2   sensitivity
% measured gas @ 5ppm SO2
< 15
CO     sensitivity
% measured gas @ 5ppm CO
< 1
H2     sensitivity
% measured gas @ 100ppm H2 
< 0.5
C2H4 sensitivity
% measured gas @ 100ppm C2H4
< 0.5
NH3   sensitivity
% measured gas @ 5ppm NH3
< 0.1
CO2   sensitivity
% measured gas @ 5% CO2
< 0.1



H2S-A4 Hydrogen Sulfide Sensor (H2S Sensor) KEY SPECIFICATIONS 
Temperature range
°C
-30 to 50
Pressure range
kPa
80 to 120
Humidity range
% rh
15 to 90
Storage period
months @ 3 to 20℃ (stored in sealed pot)
6
Load resistor
Ω (AFE circuit is recommended)
33 to 100
Weight
g
< 6


Matched Transmitter board for H2S-A4 H2S Sensor

Analogue Front End (AFE) Alphasense A4 Air Quality Sensors
The family of Analogue Front End (AFE) circuits are designed for use with the A4 air quality sensors. Connect the AFE with A4 sensors to your multtiplexed ADC and you are recording air quality data immediately.

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
精品久久久久久无码不卡| 国产偷久久久精品专区| 亚洲精品综合一二三区在线| 免费精品视频在线| 精品国产成人亚洲午夜福利| 久九九久福利精品视频视频| 日韩精品一区二区三区在线观看| 亚洲国产精品yw在线观看| 亚洲精品国产美女久久久| 国产伦精品一区二区三区在线观看 | 国产精品成久久久久三级| 亚洲精品中文字幕麻豆| 国模精品一区二区三区| 国产亚洲精品美女久久久久| 精品国产日韩久久亚洲| 精品一区二区三区免费毛片爱| 国产国拍精品亚洲AV片| 青青草99热这里都是精品| 日韩国产精品亚洲а∨天堂免| 91天堂素人精品系列全集亚洲| 国产三级精品三级在线专区1| jizzjizz国产精品久久| 国产视频精品久久| 精品无人区麻豆乱码无限制| 999精品视频在线观看| 国产精品免费大片| 99re热视频这里只精品| 国产精品无码不卡一区二区三区| 国产精品不卡高清在线观看| 国产乱人伦精品一区二区在线观看| 久久精品毛片免费观看| 久久精品亚洲综合一品| 国产三级久久久精品麻豆三级| 久久夜色撩人精品国产| 亚洲国产成人乱码精品女人久久久不卡| 日韩精品中文字幕在线观看| 欧美精品久久天天躁| 99re最新这里只有精品| 精品国产天线2019| 精品国精品国产自在久国产应用| 久久99精品久久久久久动态图|